Controlmonitoring and protection of hv motors schneiderelectric. The imm 7960 and 7990 series of relays have been specifically designed to ensure the electrical protection of high voltage and large low voltage motors. Motor protection relay for high voltage induction motor. With rare exceptions, the best method for providing overcurrent protection in these cases is to separate the overload protection devices from the shortcircuit and groundfault protection devices fig. Divide by the rated full load current from the motor nameplate. This bachelor thesis is focused on induction motor protection problems. To preset protection trip curves when protection discrimination is mandatory. After this starting time, a full voltage is applied to the induction motor, and hence, the motor runs at full speed. Aug 31, 2018 motor protection relay for high voltage induction motor august 31, 2018 february 24, 2012 by electrical4u above 90% of motors used in an industry are induction motors, because they are cheap, robust and easy to maintain. Above 90% of motors used in an industry are induction motors, because they are cheap, robust and easy to maintain. Motor and generator protection siprotec compact siemens.
It contains a full range of selectively enabled, self contained protection and control elements as detailed in the functional block diagram and features table. In these calculations, the resistance can be ignored since it is small in. These products including relaying, ctscpts, drives and resistors, automation, motors and drives, critical power, transformers, power quality. Motor data to enter motor data, click the motor settings button in the main menu to open the motor setting page. This applies to not more than 3 phase conductors in 1 conduit. Pdf protection method against induction motor single. If you can remember not to confuse motor protection with circuit protection, youll eliminate a major point of confusion in motor calculations. The key features of the motor ied include thermal overload protection, cumulative motor startup supervision, running stall protection, earthfault protection, and lossofphase protection. It must be certified as suitable as motor disconnect as per ul 508. To calculate cable size and to assist engineers during project expansion. Application of motor protection circuit breakers in. Any type of powercircuit controller variablespeed drive, etc. In the end of work practical laboratory measurements of induction motor overcurrent protection. Motor protection depending on size and voltage level.
Provides current and temperature protection, data logging, and metering. Abstract this paper discusses the fundamentals of a motor thermal model and its mathematical interpretation and physics for the different stages of motor operation. Application of multifunction motor protection relays to. How to know if you set the correct current on a motor. The sel710 motor protection relay dynamically calculates slip. Basic nec code rules and design practice wire ampacity and size 1. Event reports and trendsconfirm motor sizing, understand events, and satisfy information requirements of supervisory systems with the sel701 relays comprehensive reporting. If we setting low from fla,it can cause motor trip c0ntinues and process. Motor overload protection devices like heaters protect the motor, the motor control equipment, and the branchcircuit conductors from motor overload and the resultant excessive heating 430. Motor protective relays have the following functions built in to provide functions 1 and 2 above. If the motor current is 22a and the rated full load current is 20a, then the load factor is 2220 1. Motor protection circuit breaker and motor circuit protector. Motor induced insulation failure within the motor bearing. When providing overcurrent protection for most circuits, we use a circuit breaker that combines overcurrent protection with shortcircuit and ground fault protection.
Two speed motor protection load averaging filter for cyclic load applications reduced voltage starting supervision variable frequency filter allowing accurate sensing and calculation of the analog values in vfd applications analog input differential calculation for dual drives applications speed counter trip and alarm universal digital counter trip and alarm pulsing kwh and kvarh output trip coil supervision. Find, read and cite all the research you need on researchgate. The sel710 motor protection relay features the industrys most accurate motor protection together with settings, mounting, and communications options designed for easy application. Modular, compact design overcurrent reduction setting for maintenance dynamic thermal modeling 4line, 80character lcd display communications options for. The steps cover motor full load currents, branch circuit sizing, branch circuit overload protection, feeder sizing, and feeder over current protection sizing for single and threephase, alternating current motors of. Principles of differential relaying my protection guide. Motor protection relay setting guide electrical components. Motor protective relays have the following functions built in. To change the motor data, click the set new data button. Apply the integrated thermal protection model to retain learned motor thermal characteristics through transitional operating states start, run, stop, restart. Its preferable to use the usual over load protection mean as the main protection one and the f.
It may be advisable to select a product providing a disconnecting means as well. Sel701 motor protection relay schweitzer engineering. We specialize in the sale and support of control and power products. The time delay will be more than the starting time of the motor.
The steps cover motor full load currents, branch circuit sizing, branch circuit overload protection, feeder sizing, and feeder over current protection sizing for single and threephase, alternating current motors of more than 1 horsepower. We also looked at how to size circuit shortcircuit and groundfault protection for motor branch circuits. With these requirements, the number of singlephasing motor burnouts are greatly. Motor voltage drop calculator calculator that provides voltage drop caused by the starting of motors at the substation transformer primary and secondary leads. Disconnection and protection functions may be provided by a single device. Siprotec 7sk80 and siprotec 7sk81 are compact motor protection relays, which are designed for the protection of asynchronous motors of all sizes. Threephase motor startup supervision based on thermal stress calculation with speed switch blocking ability threephase overcurrent protection with definitetime characteristic and speed. Lift and escalator motor sizing with calculations and examples.
Fuses compl ying with ul 248 and approved for motor protection. At levine lectronics and lectric, we strive to be the premier source for all of the electrical manufacturer needs in georgia, alabama, tennessee, arkansas, mississippi, and florida. This paper presents the starting time calculation for a squirrel cage induction motor. It contains a full range of selectively enabled, self contained protection and control elements as detailed in the functional block diagram.
The relay type nm10 can be used for protection of smallmedium size motors in lv and mv systems powered. For protection calculations, motor fault level contribution is not an issue that is. Motor protection relay setting guide free ebook download as pdf. In part 1, we looked at how to size motor overloads. Medium voltage products technical guide protection. In this way, zero voltage triggering for certain time period at the starting of an induction motor deliberately reduces the starting inrush current of the induction motor. Application of multifunction motor protection relays to vfd connected motors page 3 vfd internal motor protection functions.
The motor protection relay rem610 is a versatile multifunction protection relay mainly designed to protect motors in a wide range of motor applications. Mohammed tawfeeq overcurrent protective relays overcurrent relays overcurrent relaying is the simplest and cheapest type of protection used for protection of lines, transformers, generators and motor. The sel710 with the accutrack thermal model determines the longest safe starting time no speed switch needed and reduces the wait time between motor starts up. Principles of differential relaying introduction power systems divided into zones of protection e. Number of hot start protection here we will provide the number of start allowed in specified time duration. In this video we have explained calculation for idmt over current relay setting calculation.
Since some mpcbs are suitable for use as disconnecting means as well they are. Overload relay is the one of important device for motor control. Motor protection relay for high voltage induction motor electrical4u. Siemens pti offers the following consulting services in the protection area. Fundamentals of a motor thermal model and its applications in. Fundamentals of a motor thermal model and its applications in motor protection table 1. At each point selected for calculation, the efficiency of the motor is the mechanical power output divided by the electrical power input.
Relay setting calculationidmt relayprotectionelectrical. Bulletin 140m motor protection circuit breakers mpcbs are ulcsa listed as type e manual selfprotected combination motor controllers or ulcsa listed as circuit. Starting time means the time require by the motor to reach its full speed. By this we will limit the number of hot starts given to the motor. An additional category, which is a subset within ul 508 that defines selfprotected type e devices, are added for discussion. This presentation delt with motor protection relay and its setting creteria.
We need to setting the value of overload relay properly depend on our application and motor full load ampere. The importance of starting time lies in determining the duration of large current, which flows during the starting of an induction motor. Furthermore, the thermal overload protection function can be enhanced with an optional rtd module for direct temperature measurement. You are a panel builder, electrical calculation tools can help you. Motors and branch conductors overcurrent and shortcircuit protection are not the same for motors. Overload protection protects the conductors and the motor from staying overloaded. It is a time delay so the motor has the current it needs to start. Motor protection fundamentals motor protection agenda. Motor circuit protection general a motor control circuit is a circuit of a control apparatus or system that carries the electric signal directing the performance of the controller 430. Pdf lift and escalator motor sizing with calculations. To preset protection trip unit and to display the result on the time current curve. Understanding type 2 coordinated protection in motor branch. Two speed motor protection load averaging filter for cyclic load applications reduced voltage starting supervision variable frequency filter allowing accurate sensing and calculation of the analog values in vfd applications analog input differential calculation for dual drives applications speed counter trip and alarm universal digital counter trip and alarm pulsing kwh and kvarh output trip coil supervision emergency restart input undervoltage auto restart additional element per special. This premiere motor protection scheme allows maximum start times.
The following steps adhere to article 430 of the nec. The inherent nature of the inverter portion of the vfd limits the contribution of the vfd to short circuits in the motor. Motor protection rem610 service and legacy product support. A system is designed and implemented to make protection for faults due to single phasing, voltage unbalance and under voltage in a 3ph induction motor. Basic information concerning of induction machines, its protection and diagnostic methods are included. The induction motor is made up of the stator, or stationary windings, and the rotor.
For the one motor in the group with the highest starting current find the largest fuse permitted for branch circuit protection using table 430. The product of the motor current and the applied voltage is the power input to the motor. Motor control circuit protection cooper industries. Motor protections vary widely depending on the size of the motor and voltage level involved, thus only the more common ones are discussed in this technical article. The best method for providing overcurrent protection for most circuits is to use a circuit breaker that combines overcurrent protection with shortcircuit and. Technical guide protection criteria for medium voltage. Motor protection device mpd would be to embed noninertial. General guide to low voltage motor protection code requirements the nec or cec requires that motor branch circuits be protected against overloads and short circuits. If you have motor that is constantly burning up check the overload protection or add if necessary. Application of motor protection circuit breakers in combination with varia ble frequency drives while others are not affected. Motor thermal capacity used how does the relay know r1.
A control circuit tapped on the loadside of the motor branch circuit fuse which. Electrical, mechanical, and thermal motor characteristics define the frame needed for effective motor protection running stage, starting stage, and lockedrotor conditions serve to determine the main motor parameters motor heating and thermal damage motor characteristics depend on both positiveand negativesequence current in the. Vfds typically include some basic motor protection as an integral part of the drive control system. Motor protection unit advanced motor protection model for larger, complex motors. Electric motor protection calculator electrical helper. The relay is based on a microprocessor environment. To prevent a motor from burning up, you must provide a means of protecting it from overcurrent overload, short circuit, or ground fault. If the motor in the example from step 2 had a service factor of 1. Overview of motor hazards motor protection is a challenge because there are so many different things that can go wrong with a motor and its associated load. That is why overload protection calculations are completely separate from shortcircuit and groundfault protection what is the overload protection needed. Feeders what is the correct way to size motor feeders and related overcurrent protection.
It can prevent our motor from overheat or winding burning due overload of ampere. Table c1 describes electrical calculation required for projects, tools to do the calculations, who is responsible for the calculations, and when they should be done. Overload protection may be provided by fuses, overload relays or motor thermal protectors. These calculations are required for successful implementation of protection of power system and. Modern microprocessor motor protection relays use the stator current to calculate the stator winding temperature. Thermal motor protection models give the sel710 advanced protection beyond industry standards. Motor protection rem610 service and legacy product. Fundamentals of a motor thermal model and its applications. Maximum loading for any branch circuit is 80% of rating of circuit for ampacity of wire for any load. F2 oriental motor general catalog 20032004 tec hnical reference motor sizing calculations this section describes certain items that must be calculated to find the optimum motor for a. Overcurrent protection for phase and earth faults and c2. These spreadsheets below will make your endless calculations much more easier.
If overloaded for a long enough period of time the fuse or heater protection will burn up instead of the motor and conductors. The motor protection relay rem610 is a versatile multifunction protection relay. Medium voltage products technical guide protection criteria. Induction motor theory jerry bednarczyk, pe course content introduction the ac induction motor is well suited to applications requiring constant speed operation. Rtds imbedded in the stator can be used to bias the calculated temperature if the rtds indicate that the stator temperature is hotter than the calculated value. Motor protection relay setting guide free ebook download as pdf file. Provides calculations for several alternative harmonic mitigating and filtering designs, including. Stator and is separate from the overload model for calculating thermal. Motor protection circuit breaker and motor circuit protector specifications multiple motor installation with mpcbs each motor has an individual branch circuit protective device.
In general, the induction motor is cheaper and easier to maintain compared to other alternatives. The best method for providing overcurrent protection for most circuits is to use a circuit breaker that combines overcurrent protection with shortcircuit and groundfault protection. Short circuit protection may be provided by fuses or circuit breakers. Calculation of idmt over current relay settings 505150n51n calculation model for thermal relay siemens 7sj64. Blower and motor calculations by norm christopherson this section includes information on the sizing of motor pulleys, changing rpm and cfm of blowers, motor selection for blowers, belt length changes, and using. Motor thermal capacity used how does the relay know when i. This is a fourpart study that will cover basic ac motor circuit calculations. We also can setting overload relay value depend on value of service factor motor. Threephase induction motor protection systems and its. Threephase motor startup supervision based on thermal stress calculation with speed switch blocking ability threephase overcurrent protection with definitetime characteristic and speed switch blocking ability threephase shortcircuit protection with instantaneous or definitetime characteristic.